Fan supervision explained
Each cooling fan is a 2-speed unit running on 120V with three terminals: high, low and neutral. A Hall effect sensor watches it. When no rotation is detected, or the speed is out of range, the oven raises E118 for the upper cavity and E218 for the lower one.
At a glance
| Code | E118 / E218 |
|---|---|
| Appliance | Wall Oven |
| What it means | Cooling fan supervision error for cavity 1 (E118) or cavity 2 (E218): fan speed too low or too high. |
Timing
Pull the fan motor plug, or let the motor fail, and the code comes up about 45 seconds later on the upper oven display (E218 on the lower), since the sensor sees nothing turning.
Voltage check
To test the upper fan at the control module, measure the voltage between neutral and X105 pin 3 or pin 4. This is a live-circuit measurement for a technician, who also works from Diagram 2/4.
Display and reset
- Right of the clock on digital-display ovens.
- Blinks 2 seconds on, 0.5 second off.
- + and – touched together clear it on display models.
Models
Professional Series PO301, PO302, POD301, POD302, PODC302, POM301, POMW301; the E2xx version is for two-cavity ovens only.
Related codes
- E115 / E215: an unlocked cavity running too hot
- E116: a probe error
- E303: control electronics overheating
Fan fault service, San Francisco Thermador wall ovens
A fan error calls for a technician visit, which you can request via Thermador wall oven repair at (415) 322-5620. We cover San Francisco and the Bay Area; give the model number, which cavity showed the code, and the voltage or reset steps already attempted.