Model overview
The ME302WS is listed as a double wall oven and as current. That one fact shapes the diagnosis: two cavities share a cabinet, a control module and a user interface, but each has its own sensor, latch and cooling path.
Which cavity?
Codes in the 100 series refer to cavity 1 and codes in the 200 series to cavity 2, and the lower cavity is the second one. So E101 and E201 point to an open temperature sensor in one or the other, and E118 and E218 to a cooling fan supervision error, meaning the fan speed is too low or too high. E124 and E224 are door switch errors where the switch is in an undefined state.
Symptoms and what they suggest
| You notice | A technician checks |
|---|---|
| Upper cavity heats, lower does not | That cavity’s sensor, element path and control output |
| Both cavities act strangely | Supply, control module and user interface |
| One door stays locked | The latch and door switch for that cavity |
| Fan noise after use | Cooling fan and its supervision |
Fitting notes
A double oven is tall and heavy, usually set into a tall cabinet and trimmed to match nearby panels. Pulling it out normally takes two people and clear floor in front. If the oven sits in a second-floor flat, tell us about stairs, and make sure the kitchen floor in front is protected and free of rugs.
What you can check
- Run each cavity on its own, briefly, to see which misbehaves.
- Note the code and the cavity it appeared on.
- Check the breaker, then one controlled power reset.
- Look for objects in the door area.
If you smell gas near any connected appliance, or notice burning or sparks, follow the usual rule: leave for gas, breaker off for burning.
How we handle two cavities
The technician tests each cavity separately so that a fault in one is not blamed on the other, and then looks at the shared parts, the control module and the user interface. The findings come with a written estimate that says which cavity each item concerns. Nothing is repaired without your approval, and a cavity left unrepaired can still be explained.
Related
See Thermador wall oven repair, Thermador wall ovens, Thermador oven door locked and the single-cavity Thermador ME301WS repair.
Specifications
| Dimensions | Overall height, width and depth are 52 1/16 x 29 3/4 x 24 1/2 inches. |
|---|---|
| Capacity | Each oven cavity has 4.5 cu. ft. capacity. |
| Power | Uses 240/208 V, 60 Hz power on a 40 A circuit. |
| Installation | Requires a fixed electrical connection without a plug. |
| Features | Includes two telescopic racks, one in each cavity. Includes a meat probe for the upper oven. Home Connect supports remote preheating and monitoring. |
| Finish | Combines gray glass with stainless steel. |
What sets the ME302WS apart
Two 4.5 cu. ft. cavities stacked in one frame give the owner two ovens in a single install. The upper cavity alone carries a meat probe, so probe-based cooking is an upper-oven feature. Home Connect can preheat and monitor the unit remotely, and the two telescopic racks, one in each cavity, mean each oven loads on its own.
Service notes for the ME302WS
Temperature drift is checked separately in each cavity with a standalone thermometer, because each oven has its own sensor and control. A slow preheat is checked at the heating element and the 40 A supply, since a weak supply can slow heat in one cavity. A fan, light or display fault is traced to the board or socket behind the front panel. The meat probe on the upper cavity is tested against a known reading before its input is blamed for a temperature problem. The owner can safely note which cavity is affected, the set temperature against a checked reading, and the code shown. Cut power at the 40 A breaker before any panel comes off.
Frequently asked questions
The 100 series refers to cavity 1 and the 200 series to cavity 2, with the lower cavity as the second.
A cooling fan supervision error where fan speed is too low or too high.
No, it is listed as current.
Only what you approve. We diagnose first and estimate in writing.
Error codes for this appliance